Mitsubishi Electric Air Conditioner Network System
AI controller
PAC-YG63MCA
Installation/Instruction Manual
Before using the device, carefully read this installation/instruction manual to ensure proper operation.
Keep this manual for future reference and give it to the technician when the device is reinstalled or repaired.
GB
Table of Contents
Page
1. Safety Precautions ..............................................1
2. Usage ..................................................................2
3. Parts List..............................................................2
4. Specifications ......................................................2
4-1. Device Specifications .........................2
4-2. External Dimensions...........................3
5. Example of System Configuration .......................3
6. Installation ...........................................................4
6-1. Parts Purchased Separately...............4
6-2. Installation Instructions .......................5
7. Wiring Instructions ...............................................6
7-1. Terminal Diagram ...............................6
7-2. Connecting the Power and M-NET
Transmission Lines.............................7
7-3. Connecting the Sensors .....................8
(1) Channel 1 Pt100 Input........................8
(2) Channel 1 (Channel 2)
Analog Input ......................................8
7-4. Connecting Alarm Setpoint Outputs ...9
8. Initial Settings ....................................................10
9. Dip Switch Functions .........................................12
10. LED Display Designations .................................13
10-1. Alarm Setpoint Output and Error
Displays ............................................13
10-2. Sensor and Communication Error
Displays ............................................13
11. System Operation Test......................................14
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - AI controller

Mitsubishi Electric Air Conditioner Network SystemAI controllerPAC-YG63MCAInstallation/Instruction ManualBefore using the device, carefully read this

Seite 2 - 1 Safety Precautions

97-4. Connecting Alarm Setpoint OutputsThe maximum wire length is 100 m. However, since the use of long wires makes the device susceptible to noise, u

Seite 3 - 4 Specifications

10After completing the procedures described in "6. Installation" and "7. Wiring Instructions", set the initial settings in accorda

Seite 4 - 4-2. External Dimensions

11(3) Turn on the power of this device.Verify that the LED16 (CPU power on) and LED17 (M-NET power on) are lit. (4) Set the time.Set the current time

Seite 5 - 6 Installation

12Set the dip switches for function selection according to the system to be used.At factory default, the SW01, SW02, SW03, SW08, and SW09 dipswitches

Seite 6

13The LEDs of this device indicate the upper/lower limit alarm interlock output status and error status of this device.10-1.Alarm Setpoint Output and

Seite 7 - SC50KUA

14Use the following procedure to confirm operation of the system.(1) Configure the settings of this device and the system controller while referring t

Seite 8 - S / B / A

WT04975X02Printed in JapanThis product is designed and intended for use in the residential,commercial and light-industrial environment.This product at

Seite 9

1• Thoroughly read the following safety precautions before use.• Hazards that can occur from incorrect handling are classified by the symbols below:•

Seite 10 - (Non-valtage Contacts)

2The AI controller measures temperature and humidity; it also has an alarm capability if the measurement data exceeds defined setpoints. Historical me

Seite 11 - SW06 SW07

34-2. External Dimensions[ 24 VDC Power Supply]N623Al controllerPAC-YG63MCAMODELSERVICE REF. PAC-INPUTWEIGHTSERIAL No.MADE IN JAPANYG60MCA-J VOL

Seite 12

46-1. Parts Purchased SeparatelyPrepare the following parts to install this device.[Parts to be Purchased Separately][Commercially available parts]6 I

Seite 13 - 9 Dip Switch Functions

56-2. Installation InstructionsThe AI controller PAC-YG63MCA does not have a waterproof structure.Be sure to install the AI controller inside a contro

Seite 14

6(3) Refer to "7. Wiring Instructions" and connect the wires for the power line, M-NET transmission line, output signal lines, and sensor in

Seite 15 - 11 System Operation Test

77-2. Connecting the Power and M-NET Transmission LinesS FG M-NETS / B / A (M1) (M2)UURV+/V-/FG CN02 A/B/S Tightening torque for terminal screws: 1

Seite 16 - Printed in Japan

87-3. Connecting the Sensors•For channel 1, select one of the following four types: Pt100 detection, 4 to 20 mADC, 1 to 5 VDC, or 0 to 10 VDC analog i